<?xml version="1.0" encoding="utf-8"?>


    <rss version="2.0"
         xmlns:content="http://purl.org/rss/1.0/modules/content/"
         xmlns:atom="http://www.w3.org/2005/Atom"
         xmlns:media="http://search.yahoo.com/mrss/">
        <channel>
            
                
                    <ttl>60</ttl>
                    <title>University of Bremen - Laboratory Equipment</title>
                    <link>https://www.uni-bremen.de/en/ckfs/our-research/laboratory-equipment</link>
                    <description>Laboratory equipment</description>
                    <language>en</language>
                    <copyright>University of Bremen</copyright>
                    <pubDate>Mon, 20 Apr 2026 08:39:26 +0200</pubDate>
                    <lastBuildDate>Mon, 20 Apr 2026 08:39:26 +0200</lastBuildDate>
                    <atom:link href="https://www.uni-bremen.de/en/ckfs/our-research/laboratory-equipment/rss.xml" rel="self" type="application/rss+xml"/>
                    <generator>University of Bremen</generator>
                
                
                    
                        <item>
                            <guid isPermaLink="false">content-591730</guid>
                            <pubDate>Wed, 15 May 2024 11:21:40 +0200</pubDate>
                            <title>StadiMP X-ray diffractometer</title>
                            <link>https://www.uni-bremen.de/en/ckfs/our-research/laboratory-equipment#c591730</link>
                            
                            <description>&amp;lt;p&amp;gt;StadiMP, Stoe &amp;amp;amp; Cie, Darmstadt&amp;lt;/p&amp;gt;
&amp;lt;ul&amp;gt; 	&amp;lt;li&amp;gt;Powder diffraction&amp;lt;/li&amp;gt; 	&amp;lt;li&amp;gt;Mo / Ag radiation (monochromatic)&amp;lt;/li&amp;gt; 	&amp;lt;li&amp;gt;Debye-Scherrer / Bragg-Brentano&amp;lt;/li&amp;gt; 	&amp;lt;li&amp;gt;Dectris Mythen Detector&amp;lt;/li&amp;gt; 	&amp;lt;li&amp;gt;Oxford Cryosystems PheniX (12 K - 310 K)&amp;lt;/li&amp;gt; 	&amp;lt;li&amp;gt;Anton Paar HTK 1200N (300 K - 1473 K, Bragg-Brentano and Debye-Scherrer)&amp;lt;/li&amp;gt; 	&amp;lt;li&amp;gt;Stoe HT2 (300 K - 1873 K)&amp;lt;/li&amp;gt; &amp;lt;/ul&amp;gt;
&amp;lt;p&amp;gt;&amp;lt;a class=&amp;quot;externalLink&amp;quot; href=&amp;quot;https://www.uni-bremen.de/en/mapex-cf/instrument-database/show/59?cHash=d82b0d987bf1f841b3d3e4a2909d2c34&amp;quot; target=&amp;quot;_blank&amp;quot; title=&amp;quot;Opens external link in new window&amp;quot;&amp;gt;View&amp;amp;nbsp;the instrument&amp;amp;nbsp;in&amp;amp;nbsp;the MAPEX&amp;amp;nbsp;database&amp;lt;/a&amp;gt;&amp;lt;/p&amp;gt;</description>
                            
                            <category>Content</category>
                            
                            
                        </item>
                    
                
                    
                        <item>
                            <guid isPermaLink="false">content-591731</guid>
                            <pubDate>Thu, 16 May 2024 16:16:32 +0200</pubDate>
                            <title>D8 Discover X-ray diffractometer</title>
                            <link>https://www.uni-bremen.de/en/ckfs/our-research/laboratory-equipment#c591731</link>
                            
                            <description>&amp;lt;p&amp;gt;D8 Discover,&amp;amp;nbsp;Bruker AXS, Karlsruhe&amp;lt;/p&amp;gt;
&amp;lt;ul&amp;gt; 	&amp;lt;li&amp;gt;Powder diffraction&amp;lt;/li&amp;gt; 	&amp;lt;li&amp;gt;Cu radiation&amp;lt;/li&amp;gt; 	&amp;lt;li&amp;gt;LynxEye Detector&amp;lt;/li&amp;gt; 	&amp;lt;li&amp;gt;HTK-1200N&amp;lt;/li&amp;gt; &amp;lt;/ul&amp;gt;</description>
                            
                            <category>Content</category>
                            
                            
                        </item>
                    
                
                    
                        <item>
                            <guid isPermaLink="false">content-591732</guid>
                            <pubDate>Wed, 15 May 2024 11:25:20 +0200</pubDate>
                            <title>D8 Venture X-ray diffractometer</title>
                            <link>https://www.uni-bremen.de/en/ckfs/our-research/laboratory-equipment#c591732</link>
                            
                            <description>&amp;lt;p&amp;gt;D8 Discover, Bruker AXS, Karlsruhe&amp;lt;/p&amp;gt;
&amp;lt;ul&amp;gt; 	&amp;lt;li&amp;gt;Single crystal diffraction&amp;lt;/li&amp;gt; 	&amp;lt;li&amp;gt;Mo radiation&amp;lt;/li&amp;gt; 	&amp;lt;li&amp;gt;Operating temperature: 173 K - 1273 K&amp;lt;/li&amp;gt; &amp;lt;/ul&amp;gt;
&amp;lt;p&amp;gt;&amp;lt;a class=&amp;quot;externalLink&amp;quot; href=&amp;quot;https://www.uni-bremen.de/en/mapex-cf/instrument-database/show/4?cHash=c431708017f4570582870f33b53966b7&amp;quot; target=&amp;quot;_blank&amp;quot; title=&amp;quot;Opens external link in new window&amp;quot;&amp;gt;View&amp;amp;nbsp;the instrument&amp;amp;nbsp;in&amp;amp;nbsp;the MAPEX&amp;amp;nbsp;database&amp;lt;/a&amp;gt;&amp;lt;/p&amp;gt;</description>
                            
                            <category>Content</category>
                            
                            
                        </item>
                    
                
                    
                        <item>
                            <guid isPermaLink="false">content-591733</guid>
                            <pubDate>Wed, 15 May 2024 11:28:35 +0200</pubDate>
                            <title>Scanning Electron Microscope (SEM)</title>
                            <link>https://www.uni-bremen.de/en/ckfs/our-research/laboratory-equipment#c591733</link>
                            
                            <description>&amp;lt;p&amp;gt;JSM-6510, Jeol (Germany) GmbH, Freising&amp;lt;/p&amp;gt;
&amp;lt;p&amp;gt;Scanning electron miscroscope&amp;lt;/p&amp;gt;
&amp;lt;ul&amp;gt; 	&amp;lt;li&amp;gt;Tungsten cathode&amp;lt;/li&amp;gt; 	&amp;lt;li&amp;gt;Resolution (theor.): 3 nm @ 30 kV&amp;lt;/li&amp;gt; &amp;lt;/ul&amp;gt;
&amp;lt;p&amp;gt;Detectors:&amp;lt;/p&amp;gt;
&amp;lt;ul&amp;gt; 	&amp;lt;li&amp;gt;Secondary electrons&amp;lt;/li&amp;gt; 	&amp;lt;li&amp;gt;Backscattered electrons&amp;lt;/li&amp;gt; 	&amp;lt;li&amp;gt;X-ray spectrum&amp;lt;/li&amp;gt; &amp;lt;/ul&amp;gt;
&amp;lt;p&amp;gt;&amp;lt;a class=&amp;quot;externalLink&amp;quot; href=&amp;quot;https://www.uni-bremen.de/en/mapex-cf/instrument-database/show/22?cHash=3528889d84a051ea06c822a55b91e2ac&amp;quot; target=&amp;quot;_blank&amp;quot; title=&amp;quot;Opens external link in new window&amp;quot;&amp;gt;View&amp;amp;nbsp;the instrument&amp;amp;nbsp;in&amp;amp;nbsp;the MAPEX&amp;amp;nbsp;database&amp;lt;/a&amp;gt;&amp;lt;/p&amp;gt;</description>
                            
                            <category>Content</category>
                            
                            
                        </item>
                    
                
                    
                        <item>
                            <guid isPermaLink="false">content-591734</guid>
                            <pubDate>Wed, 15 May 2024 11:31:05 +0200</pubDate>
                            <title>Raman Spectroscope</title>
                            <link>https://www.uni-bremen.de/en/ckfs/our-research/laboratory-equipment#c591734</link>
                            
                            <description>&amp;lt;p&amp;gt;LabRam ARAMIS, Horiba Jobin Yvon&amp;lt;/p&amp;gt;
&amp;lt;ul&amp;gt; 	&amp;lt;li&amp;gt;Lasers: 532 nm, 633 nm and 785 nm&amp;lt;/li&amp;gt; 	&amp;lt;li&amp;gt;Measuring range: 35 - 8000 cm&amp;lt;sup&amp;gt;-1&amp;lt;/sup&amp;gt;(with 532 nm), 100 - 6000 cm&amp;lt;sup&amp;gt;-1&amp;lt;/sup&amp;gt;(with 633 nm), 100 - 2200 cm&amp;lt;sup&amp;gt;-1&amp;lt;/sup&amp;gt;(with 785 nm)&amp;lt;/li&amp;gt; 	&amp;lt;li&amp;gt;Stokes: Yes (with 532 nm), Yes (with 633 nm), Yes (with 785 nm)&amp;lt;/li&amp;gt; 	&amp;lt;li&amp;gt;Anti-Stokes: Yes (with 532 nm), No (with 633 nm), No (with 785 nm)&amp;lt;/li&amp;gt; 	&amp;lt;li&amp;gt;Temperature range: 78 to 1773 K&amp;lt;/li&amp;gt; 	&amp;lt;li&amp;gt;Sample states: powder, single crystal, pellet, liquid, gas, amorphous, microcrystalline, nanocrystalline and quantum dots&amp;lt;/li&amp;gt; 	&amp;lt;li&amp;gt;In-situ measurement: Yes&amp;lt;/li&amp;gt; &amp;lt;/ul&amp;gt;
&amp;lt;p&amp;gt;&amp;lt;a class=&amp;quot;externalLink&amp;quot; href=&amp;quot;https://www.uni-bremen.de/mapex-cf/instrument-database/show/50?cHash=e81a568967a977bef365c5f831ec1fde&amp;quot; target=&amp;quot;_blank&amp;quot; title=&amp;quot;Opens external link in new window&amp;quot;&amp;gt;View&amp;amp;nbsp;the instrument&amp;amp;nbsp;in&amp;amp;nbsp;the MAPEX&amp;amp;nbsp;database&amp;lt;/a&amp;gt;&amp;lt;/p&amp;gt;</description>
                            
                            <category>Content</category>
                            
                            
                        </item>
                    
                
                    
                        <item>
                            <guid isPermaLink="false">content-591735</guid>
                            <pubDate>Wed, 13 Nov 2024 14:02:33 +0100</pubDate>
                            <title>Fourier-Transform-Infrared-Spectroscope (FT-IR)</title>
                            <link>https://www.uni-bremen.de/en/ckfs/our-research/laboratory-equipment#c591735</link>
                            
                            <description>&amp;lt;p&amp;gt;VERTEX 80v FT-IR Spectrometer, Bruker Optics&amp;lt;/p&amp;gt;
&amp;lt;ul&amp;gt; 	&amp;lt;li&amp;gt;Measuring range: 10-300 cm&amp;lt;sup&amp;gt;-1&amp;lt;/sup&amp;gt; (FIR), 400-4000 cm&amp;lt;sup&amp;gt;-1&amp;lt;/sup&amp;gt; (MIR), 4000-20000 cm&amp;lt;sup&amp;gt;-1&amp;lt;/sup&amp;gt;(NIR)&amp;lt;/li&amp;gt; 	&amp;lt;li&amp;gt;Sample conditions: powder, single crystal, pellet&amp;lt;/li&amp;gt; 	&amp;lt;li&amp;gt;Temperature range: 80 to 1773 K&amp;lt;/li&amp;gt; &amp;lt;/ul&amp;gt;
&amp;lt;p&amp;gt;&amp;lt;a class=&amp;quot;externalLink&amp;quot; href=&amp;quot;https://www.uni-bremen.de/mapex-cf/instrument-database/show/49?cHash=4111c9db0484cbfbf1fd447b4f5767ba&amp;quot; target=&amp;quot;_blank&amp;quot; title=&amp;quot;Opens external link in new window&amp;quot;&amp;gt;View&amp;amp;nbsp;the instrument&amp;amp;nbsp;in&amp;amp;nbsp;the MAPEX&amp;amp;nbsp;database&amp;lt;/a&amp;gt;&amp;lt;/p&amp;gt;</description>
                            
                            <category>Content</category>
                            
                            
                        </item>
                    
                
                    
                        <item>
                            <guid isPermaLink="false">content-591736</guid>
                            <pubDate>Wed, 15 May 2024 12:44:36 +0200</pubDate>
                            <title>UV-Vis Spectrophotometer</title>
                            <link>https://www.uni-bremen.de/en/ckfs/our-research/laboratory-equipment#c591736</link>
                            
                            <description>&amp;lt;p&amp;gt;UV-Vis spectrophotometer, Shimadzu&amp;lt;/p&amp;gt;
&amp;lt;ul&amp;gt; 	&amp;lt;li&amp;gt;Spectroscopic analysis of liquids and solids&amp;lt;/li&amp;gt; 	&amp;lt;li&amp;gt;Measuring range: 190 nm to 1100 nm&amp;lt;/li&amp;gt; 	&amp;lt;li&amp;gt;Resolution: 0.01 nm to 5.0 nm&amp;lt;/li&amp;gt; 	&amp;lt;li&amp;gt;UV-Vis accessory for diffuse reflection (UV-Vis DiffusIR(TM), Pike Technologies Inc.)&amp;lt;/li&amp;gt; 	&amp;lt;li&amp;gt;Temperature-dependent measurements in the range 273 K to 1273 K (temperature chamber, Pike Technologies Inc.)&amp;amp;nbsp;&amp;lt;/li&amp;gt; 	&amp;lt;li&amp;gt;Software: UVProbe 2.70, TempPro(TM)&amp;lt;/li&amp;gt; &amp;lt;/ul&amp;gt;</description>
                            
                            <category>Content</category>
                            
                            
                        </item>
                    
                
                    
                        <item>
                            <guid isPermaLink="false">content-591737</guid>
                            <pubDate>Wed, 15 May 2024 13:00:57 +0200</pubDate>
                            <title>Differential Scanning Calorimetry (DSC)</title>
                            <link>https://www.uni-bremen.de/en/ckfs/our-research/laboratory-equipment#c591737</link>
                            
                            <description>&amp;lt;p&amp;gt;STARe System TGA/DSC 3+, Mettler Toledo&amp;lt;/p&amp;gt;
&amp;lt;ul&amp;gt; 	&amp;lt;li&amp;gt;Technology: differential scanning calorimetry (DSC)&amp;lt;/li&amp;gt; 	&amp;lt;li&amp;gt;Sensor: heat flow&amp;lt;/li&amp;gt; 	&amp;lt;li&amp;gt;Temperature range: 123 K - 973 K&amp;lt;/li&amp;gt; 	&amp;lt;li&amp;gt;Sampling rate: max 50 data points/s&amp;lt;/li&amp;gt; 	&amp;lt;li&amp;gt;Heating rate per min.: 0.02 K - 300 K&amp;lt;/li&amp;gt; 	&amp;lt;li&amp;gt;Cooling rate per min.: 0.02 K - 50 K&amp;lt;/li&amp;gt; &amp;lt;/ul&amp;gt;</description>
                            
                            <category>Content</category>
                            
                            
                        </item>
                    
                
                    
                        <item>
                            <guid isPermaLink="false">content-591738</guid>
                            <pubDate>Wed, 15 May 2024 12:57:51 +0200</pubDate>
                            <title>Thermogravimetric Analysis (TGA) with DSC</title>
                            <link>https://www.uni-bremen.de/en/ckfs/our-research/laboratory-equipment#c591738</link>
                            
                            <description>&amp;lt;p&amp;gt;STARe System TGA/DSC 3+, Mettler Toledo&amp;lt;/p&amp;gt;
&amp;lt;ul&amp;gt; 	&amp;lt;li&amp;gt;Technology: simultaneous thermal analysis (TGA/DSC), differential scanning calorimetry (DSC), thermogravimetry (TGA)&amp;lt;/li&amp;gt; 	&amp;lt;li&amp;gt;Sensor: mass, heat flow&amp;lt;/li&amp;gt; 	&amp;lt;li&amp;gt;Temperature range: 303 K - 1873 K&amp;lt;/li&amp;gt; 	&amp;lt;li&amp;gt;Sampling rate: 10 data points/s&amp;lt;/li&amp;gt; 	&amp;lt;li&amp;gt;Heating rate per min.: 2 K - 250 K&amp;lt;/li&amp;gt; 	&amp;lt;li&amp;gt;Cooling rate per min.: 0.02 K - 50 K&amp;lt;/li&amp;gt; &amp;lt;/ul&amp;gt;</description>
                            
                            <category>Content</category>
                            
                            
                        </item>
                    
                
                    
                        <item>
                            <guid isPermaLink="false">content-591739</guid>
                            <pubDate>Wed, 15 May 2024 13:06:22 +0200</pubDate>
                            <title>Digital Lightmicroscope (LM)</title>
                            <link>https://www.uni-bremen.de/en/ckfs/our-research/laboratory-equipment#c591739</link>
                            
                            <description>&amp;lt;p&amp;gt;Axio Imager M2m, ZEISS&amp;lt;/p&amp;gt;
&amp;lt;p&amp;gt;For materials research, upright research microscope for sophisticated imaging in fluorescence and transmitted light.&amp;lt;/p&amp;gt;
&amp;lt;ul&amp;gt; 	&amp;lt;li&amp;gt;Reflected light and transmitted light microscopy&amp;lt;/li&amp;gt; 	&amp;lt;li&amp;gt;Polarization microscopy using an analyser slider&amp;lt;/li&amp;gt; 	&amp;lt;li&amp;gt;Software-supported image evaluation (ZEISS ZENN)&amp;lt;/li&amp;gt; 	&amp;lt;li&amp;gt;Temperature-dependent measurements in the range 77 K to 873 K (LINKAM stage: THMS600)&amp;lt;/li&amp;gt; 	&amp;lt;li&amp;gt;Non-destructive examination of samples&amp;lt;/li&amp;gt; &amp;lt;/ul&amp;gt;</description>
                            
                            <category>Content</category>
                            
                            
                        </item>
                    
                
                    
                        <item>
                            <guid isPermaLink="false">content-591740</guid>
                            <pubDate>Wed, 15 May 2024 13:07:31 +0200</pubDate>
                            <title>Photocatalysis Testsystem 1</title>
                            <link>https://www.uni-bremen.de/en/ckfs/our-research/laboratory-equipment#c591740</link>
                            
                            <description>&amp;lt;p&amp;gt;Standardized test system 1 (STD1)&amp;lt;/p&amp;gt;
&amp;lt;ul&amp;gt; 	&amp;lt;li&amp;gt;Exploratory investigation of photocatalytically active materials&amp;lt;/li&amp;gt; 	&amp;lt;li&amp;gt;Measurement type: &amp;quot;ex situ&amp;quot;&amp;lt;/li&amp;gt; 	&amp;lt;li&amp;gt;Probing investigation of photocatalytically active materials&amp;lt;/li&amp;gt; 	&amp;lt;li&amp;gt;Excitation sources (LEDs) in the range: approx. 275 nm, 385 nm, 460 nm, 660 nm, white light (380-850 nm)&amp;lt;/li&amp;gt; 	&amp;lt;li&amp;gt;Sample holder: Measuring cuvettes&amp;lt;/li&amp;gt; 	&amp;lt;li&amp;gt;Sample form: powder&amp;lt;/li&amp;gt; 	&amp;lt;li&amp;gt;Measuring times in the range from minutes to hours&amp;lt;/li&amp;gt; 	&amp;lt;li&amp;gt;Dyes: methylene blue, methyl orange, nitrophenols&amp;lt;/li&amp;gt; &amp;lt;/ul&amp;gt;</description>
                            
                            <category>Content</category>
                            
                            
                        </item>
                    
                
                    
                        <item>
                            <guid isPermaLink="false">content-591741</guid>
                            <pubDate>Wed, 15 May 2024 13:08:22 +0200</pubDate>
                            <title>Photocatalysis Testsystem 2</title>
                            <link>https://www.uni-bremen.de/en/ckfs/our-research/laboratory-equipment#c591741</link>
                            
                            <description>&amp;lt;p&amp;gt;Standardized Test System 2 (STD2)&amp;lt;/p&amp;gt;
&amp;lt;ul&amp;gt; 	&amp;lt;li&amp;gt;Systematic investigation of photocatalytically active materials&amp;lt;/li&amp;gt; 	&amp;lt;li&amp;gt;Type of measurement: &amp;quot;ex situ&amp;quot;&amp;lt;/li&amp;gt; 	&amp;lt;li&amp;gt;Excitation sources (LEDs) in the range: approx. 275 nm, 385 nm, 460 nm, 660 nm, white light (380-850 nm)&amp;lt;/li&amp;gt; 	&amp;lt;li&amp;gt;Sample holder: photocatalytic reaction vessel with integrated measuring cuvette&amp;lt;/li&amp;gt; 	&amp;lt;li&amp;gt;Sample shape: layers on ceramic substrates&amp;lt;/li&amp;gt; 	&amp;lt;li&amp;gt;Measuring times in the range from minutes to hours&amp;lt;/li&amp;gt; 	&amp;lt;li&amp;gt;Dyes: methylene blue, methyl orange, nitrophenols&amp;lt;/li&amp;gt; &amp;lt;/ul&amp;gt;</description>
                            
                            <category>Content</category>
                            
                            
                        </item>
                    
                
                    
                        <item>
                            <guid isPermaLink="false">content-591742</guid>
                            <pubDate>Wed, 15 May 2024 13:08:59 +0200</pubDate>
                            <title>Photocatalysis Testsystem 3</title>
                            <link>https://www.uni-bremen.de/en/ckfs/our-research/laboratory-equipment#c591742</link>
                            
                            <description>&amp;lt;p&amp;gt;Standardized Test System 3 (STD3)&amp;lt;/p&amp;gt;
&amp;lt;ul&amp;gt; 	&amp;lt;li&amp;gt;Systematic investigation of photocatalytically active materials&amp;lt;/li&amp;gt; 	&amp;lt;li&amp;gt;Type of measurement: &amp;quot;in operando&amp;quot;&amp;lt;/li&amp;gt; 	&amp;lt;li&amp;gt;Excitation sources (LEDs) in the range: approx. 275 nm, 385 nm, 460 nm, 660 nm, white light (380-850 nm)&amp;lt;/li&amp;gt; 	&amp;lt;li&amp;gt;Sample holder: flow cell&amp;lt;/li&amp;gt; 	&amp;lt;li&amp;gt;Sample form: layers on microscope slides&amp;lt;/li&amp;gt; 	&amp;lt;li&amp;gt;Measuring times in the range from minutes to hours&amp;lt;/li&amp;gt; 	&amp;lt;li&amp;gt;Dyes: methylene blue, methyl orange, nitrophenols&amp;lt;/li&amp;gt; &amp;lt;/ul&amp;gt;</description>
                            
                            <category>Content</category>
                            
                            
                        </item>
                    
                
                    
                        <item>
                            <guid isPermaLink="false">content-591743</guid>
                            <pubDate>Thu, 16 May 2024 10:18:34 +0200</pubDate>
                            <title>Hydrothermal System</title>
                            <link>https://www.uni-bremen.de/en/ckfs/our-research/laboratory-equipment#c591743</link>
                            
                            <description>&amp;lt;p&amp;gt;Hydrothermal system digestec DAB-2,&amp;amp;nbsp;Berghof&amp;lt;/p&amp;gt;
&amp;lt;p&amp;gt;For syntheses and digestions under high pressure.&amp;lt;/p&amp;gt;
&amp;lt;ul&amp;gt; 	&amp;lt;li&amp;gt;Working pressure: up to 200 bar&amp;lt;/li&amp;gt; 	&amp;lt;li&amp;gt;Temperature: up to 473 K&amp;lt;/li&amp;gt; 	&amp;lt;li&amp;gt;6 slots&amp;lt;/li&amp;gt; 	&amp;lt;li&amp;gt;Filling height Teflon sleeve: 50 mL&amp;lt;/li&amp;gt; 	&amp;lt;li&amp;gt;Programmable pressure and temperature control&amp;lt;/li&amp;gt; &amp;lt;/ul&amp;gt;</description>
                            
                            <category>Content</category>
                            
                            
                        </item>
                    
                
                    
                        <item>
                            <guid isPermaLink="false">content-591744</guid>
                            <pubDate>Thu, 16 May 2024 10:18:09 +0200</pubDate>
                            <title>Chamber- and Tubefurnaces</title>
                            <link>https://www.uni-bremen.de/en/ckfs/our-research/laboratory-equipment#c591744</link>
                            
                            <description>&amp;lt;p&amp;gt;Chamber furnace CWF1200,&amp;amp;nbsp;Carbolite (picture top left)&amp;lt;/p&amp;gt;
&amp;lt;ul&amp;gt; 	&amp;lt;li&amp;gt;Room temperature up to 1150°C with various heating rates and holding times possible (also 1200°C for a short time)&amp;lt;/li&amp;gt; &amp;lt;/ul&amp;gt;
&amp;lt;p&amp;gt;&amp;lt;br /&amp;gt; Chamber furnace RHF1600,&amp;amp;nbsp;Carbolite (picture top right)&amp;lt;/p&amp;gt;
&amp;lt;ul&amp;gt; 	&amp;lt;li&amp;gt;Room temperature up to 1550°C with various heating rates and holding times possible (also 1600°C for a short time)&amp;lt;/li&amp;gt; &amp;lt;/ul&amp;gt;
&amp;lt;p&amp;gt;&amp;lt;br /&amp;gt; Chamber furnace 1500,&amp;amp;nbsp;Nabertherm (bottom left)&amp;lt;/p&amp;gt;
&amp;lt;ul&amp;gt; 	&amp;lt;li&amp;gt;Room temperature up to 1450°C with various heating rates and holding times possible (also 1500°C for a short time)&amp;lt;/li&amp;gt; &amp;lt;/ul&amp;gt;
&amp;lt;p&amp;gt;&amp;lt;br /&amp;gt; Tube furnace TZF 12/65/550,&amp;amp;nbsp; Carbolite&amp;amp;nbsp;(bottom right)&amp;lt;/p&amp;gt;
&amp;lt;ul&amp;gt; 	&amp;lt;li&amp;gt;Room temperature up to 1150°C with various heating rates and holding times possible (also 1200°C for a short time)&amp;lt;/li&amp;gt; &amp;lt;/ul&amp;gt;

</description>
                            
                            <category>Content</category>
                            
                            
                        </item>
                    
                
                    
                        <item>
                            <guid isPermaLink="false">content-591745</guid>
                            <pubDate>Wed, 15 May 2024 13:15:46 +0200</pubDate>
                            <title>Kugelmühle</title>
                            <link>https://www.uni-bremen.de/en/ckfs/our-research/laboratory-equipment#c591745</link>
                            
                            <description>&amp;lt;p&amp;gt;High Energy Ball Mill Emax, Retsch GmbH&amp;lt;/p&amp;gt;
&amp;lt;p&amp;gt;Usages: chemical homogenizing, nano grinding, crystallite size reduction (down to ~20 nm).&amp;amp;nbsp;Integrated with water cooling system to prevent the sample from overheating.&amp;lt;/p&amp;gt;
&amp;lt;ul&amp;gt; 	&amp;lt;li&amp;gt;Milling frequency = 300 - 1200 rpm&amp;lt;/li&amp;gt; 	&amp;lt;li&amp;gt;Milling time = maximum 6 h/day&amp;lt;/li&amp;gt; 	&amp;lt;li&amp;gt;Milling condition = dry / wet (with ethanol)&amp;lt;/li&amp;gt; 	&amp;lt;li&amp;gt;Milling jar 	&amp;lt;ul&amp;gt; 		&amp;lt;li&amp;gt;Material = WC (tungsten carbide)&amp;lt;/li&amp;gt; 		&amp;lt;li&amp;gt;Capacity = 50 mL (~20 mL should be left empty)&amp;lt;/li&amp;gt; 	&amp;lt;/ul&amp;gt; 	&amp;lt;/li&amp;gt; 	&amp;lt;li&amp;gt;Milling balls 	&amp;lt;ul&amp;gt; 		&amp;lt;li&amp;gt;Material = WC (tungsten carbide)&amp;lt;/li&amp;gt; 		&amp;lt;li&amp;gt;Diameter = 2 mm&amp;lt;/li&amp;gt; 	&amp;lt;/ul&amp;gt; 	&amp;lt;/li&amp;gt; &amp;lt;/ul&amp;gt;</description>
                            
                            <category>Content</category>
                            
                            
                        </item>
                    
                
                    
                        <item>
                            <guid isPermaLink="false">content-591746</guid>
                            <pubDate>Wed, 15 May 2024 13:16:22 +0200</pubDate>
                            <title>Additive Fertigung (3D-Druck)</title>
                            <link>https://www.uni-bremen.de/en/ckfs/our-research/laboratory-equipment#c591746</link>
                            
                            <description>&amp;lt;p&amp;gt;Ultimaker 2 Extended, Ultimaker&amp;lt;/p&amp;gt;
&amp;lt;ul&amp;gt; 	&amp;lt;li&amp;gt;Filament-Drucker&amp;lt;/li&amp;gt; 	&amp;lt;li&amp;gt;Filamentdurchmesser: 2.85 mm&amp;lt;/li&amp;gt; 	&amp;lt;li&amp;gt;Filamente: PLA, PMMA unterschiedlich pigmentiert&amp;lt;/li&amp;gt; 	&amp;lt;li&amp;gt;Düsendurchmesser: 0.25 mm, 0.40 mm, 0.60 mm, 0.80 mm&amp;lt;/li&amp;gt; 	&amp;lt;li&amp;gt;Druckqualität: 0.015 mm&amp;lt;/li&amp;gt; 	&amp;lt;li&amp;gt;Maximale Druckbetttemperatur: 100 °C&amp;lt;/li&amp;gt; 	&amp;lt;li&amp;gt;Druckgeschwindigkeit: optimal 30 mm/s&amp;lt;/li&amp;gt; &amp;lt;/ul&amp;gt;</description>
                            
                            <category>Content</category>
                            
                            
                        </item>
                    
                
                    
                        <item>
                            <guid isPermaLink="false">content-591747</guid>
                            <pubDate>Wed, 15 May 2024 13:14:12 +0200</pubDate>
                            <title>Welding Microscope</title>
                            <link>https://www.uni-bremen.de/en/ckfs/our-research/laboratory-equipment#c591747</link>
                            
                            <description>&amp;lt;p&amp;gt;Welding microscope with PUK 3s professional, Lampert Werktechnik GmbH, Werneck Germany&amp;lt;/p&amp;gt;
&amp;lt;ul&amp;gt; 	&amp;lt;li&amp;gt;Power consumption: 350 VA&amp;lt;/li&amp;gt; 	&amp;lt;li&amp;gt;Shielding gas: Argon&amp;lt;/li&amp;gt; 	&amp;lt;li&amp;gt;Magnification: 1 - 10x&amp;lt;/li&amp;gt; &amp;lt;/ul&amp;gt;</description>
                            
                            <category>Content</category>
                            
                            
                        </item>
                    
                
                    
                        <item>
                            <guid isPermaLink="false">content-591748</guid>
                            <pubDate>Wed, 15 May 2024 13:14:47 +0200</pubDate>
                            <title>Diamond Wheel Saw</title>
                            <link>https://www.uni-bremen.de/en/ckfs/our-research/laboratory-equipment#c591748</link>
                            
                            <description>&amp;lt;p&amp;gt;Diamond wheel saw, Well Diamantdrahtsägen GmbH, Mannheim Germany&amp;lt;/p&amp;gt;</description>
                            
                            <category>Content</category>
                            
                            