Laboratory Equipment

STADI MP X-ray diffractometer

StadiMP X-ray diffractometer

StadiMP, Stoe & Cie, Darmstadt

  • Powder diffraction
  • Mo / Ag radiation (monochromatic)
  • Debye-Scherrer / Bragg-Brentano
  • Dectris Mythen Detector
  • Oxford Cryosystems PheniX (12 K - 310 K)
  • Anton Paar HTK 1200N (300 K - 1473 K, Bragg-Brentano and Debye-Scherrer)
  • Stoe HT2 (300 K - 1873 K)

View the instrument in the MAPEX database

D8 Discover

D8 Discover X-ray diffractometer

D8 Discover, Bruker AXS, Karlsruhe

  • Powder diffraction
  • Cu radiation
  • LynxEye Detector
  • HTK-1200N
D8 Venture

D8 Venture X-ray diffractometer

D8 Discover, Bruker AXS, Karlsruhe

  • Single crystal diffraction
  • Mo radiation
  • Operating temperature: 173 K - 1273 K

View the instrument in the MAPEX database

Scanning electron microscope

Scanning Electron Microscope (SEM)

JSM-6510, Jeol (Germany) GmbH, Freising

Scanning electron miscroscope

  • Tungsten cathode
  • Resolution (theor.): 3 nm @ 30 kV

Detectors:

  • Secondary electrons
  • Backscattered electrons
  • X-ray spectrum

View the instrument in the MAPEX database

Raman spektroscope

Raman Spectroscope

LabRam ARAMIS, Horiba Jobin Yvon

  • Lasers: 532 nm, 633 nm and 785 nm
  • Measuring range: 35 - 8000 cm-1(with 532 nm), 100 - 6000 cm-1(with 633 nm), 100 - 2200 cm-1(with 785 nm)
  • Stokes: Yes (with 532 nm), Yes (with 633 nm), Yes (with 785 nm)
  • Anti-Stokes: Yes (with 532 nm), No (with 633 nm), No (with 785 nm)
  • Temperature range: 78 to 1773 K
  • Sample states: powder, single crystal, pellet, liquid, gas, amorphous, microcrystalline, nanocrystalline and quantum dots
  • In-situ measurement: Yes

View the instrument in the MAPEX database

FT-IR spektroscope

Fourier-Transform-Infrared-Spectroscope (FT-IR)

IFS 66v/S FT-IR spectrometer, Bruker Optics

  • Measuring range: 10-300 cm-1 (FIR), 400-4000 cm-1 (MIR), 100- cm-1(NIR)
  • Sample conditions: powder, single crystal, pellet
  • Temperature range: 80 to 1773 K
  • Gas flow: Yes

View the instrument in the MAPEX database

UV-Vis spectrophotometer

UV-Vis Spectrophotometer

UV-Vis spectrophotometer, Shimadzu

  • Spectroscopic analysis of liquids and solids
  • Measuring range: 190 nm to 1100 nm
  • Resolution: 0.01 nm to 5.0 nm
  • UV-Vis accessory for diffuse reflection (UV-Vis DiffusIR(TM), Pike Technologies Inc.)
  • Temperature-dependent measurements in the range 273 K to 1273 K (temperature chamber, Pike Technologies Inc.) 
  • Software: UVProbe 2.70, TempPro(TM)
Differential scanning calorimeter (DSC)

Differential Scanning Calorimetry (DSC)

STARe System TGA/DSC 3+, Mettler Toledo

  • Technology: differential scanning calorimetry (DSC)
  • Sensor: heat flow
  • Temperature range: 123 K - 973 K
  • Sampling rate: max 50 data points/s
  • Heating rate per min.: 0.02 K - 300 K
  • Cooling rate per min.: 0.02 K - 50 K
Thermogravimetric analysis (TGA) with differential scanning calorimetry (DSC)

Thermogravimetric Analysis (TGA) with DSC

STARe System TGA/DSC 3+, Mettler Toledo

  • Technology: simultaneous thermal analysis (TGA/DSC), differential scanning calorimetry (DSC), thermogravimetry (TGA)
  • Sensor: mass, heat flow
  • Temperature range: 303 K - 1873 K
  • Sampling rate: 10 data points/s
  • Heating rate per min.: 2 K - 250 K
  • Cooling rate per min.: 0.02 K - 50 K
Digital lightmicroscope

Digital Lightmicroscope (LM)

Axio Imager M2m, ZEISS

For materials research, upright research microscope for sophisticated imaging in fluorescence and transmitted light.

  • Reflected light and transmitted light microscopy
  • Polarization microscopy using an analyser slider
  • Software-supported image evaluation (ZEISS ZENN)
  • Temperature-dependent measurements in the range 77 K to 873 K (LINKAM stage: THMS600)
  • Non-destructive examination of samples
Standardized Test System 1 (STD1)

Photocatalysis Testsystem 1

Standardized test system 1 (STD1)

  • Exploratory investigation of photocatalytically active materials
  • Measurement type: "ex situ"
  • Probing investigation of photocatalytically active materials
  • Excitation sources (LEDs) in the range: approx. 275 nm, 385 nm, 460 nm, 660 nm, white light (380-850 nm)
  • Sample holder: Measuring cuvettes
  • Sample form: powder
  • Measuring times in the range from minutes to hours
  • Dyes: methylene blue, methyl orange, nitrophenols
Standardized Test System 2 (STD2)

Photocatalysis Testsystem 2

Standardized Test System 2 (STD2)

  • Systematic investigation of photocatalytically active materials
  • Type of measurement: "ex situ"
  • Excitation sources (LEDs) in the range: approx. 275 nm, 385 nm, 460 nm, 660 nm, white light (380-850 nm)
  • Sample holder: photocatalytic reaction vessel with integrated measuring cuvette
  • Sample shape: layers on ceramic substrates
  • Measuring times in the range from minutes to hours
  • Dyes: methylene blue, methyl orange, nitrophenols
Standardized Test System 3 (STD3)

Photocatalysis Testsystem 3

Standardized Test System 3 (STD3)

  • Systematic investigation of photocatalytically active materials
  • Type of measurement: "in operando"
  • Excitation sources (LEDs) in the range: approx. 275 nm, 385 nm, 460 nm, 660 nm, white light (380-850 nm)
  • Sample holder: flow cell
  • Sample form: layers on microscope slides
  • Measuring times in the range from minutes to hours
  • Dyes: methylene blue, methyl orange, nitrophenols
Hydrothermal Oven

Hydrothermal System

Hydrothermal system digestec DAB-2, Berghof

For syntheses and digestions under high pressure.

  • Working pressure: up to 200 bar
  • Temperature: up to 473 K
  • 6 slots
  • Filling height Teflon sleeve: 50 mL
  • Programmable pressure and temperature control
Chamber oven 1200
Chamber oven 1600
Chamber oven 1500
Tube furnance

Chamber- and Tubefurnaces

Chamber furnace CWF1200, Carbolite (picture top left)

  • Room temperature up to 1150°C with various heating rates and holding times possible (also 1200°C for a short time)


Chamber furnace RHF1600, Carbolite (picture top right)

  • Room temperature up to 1550°C with various heating rates and holding times possible (also 1600°C for a short time)


Chamber furnace 1500, Nabertherm (bottom left)

  • Room temperature up to 1450°C with various heating rates and holding times possible (also 1500°C for a short time)


Tube furnace TZF 12/65/550,  Carbolite (bottom right)

  • Room temperature up to 1150°C with various heating rates and holding times possible (also 1200°C for a short time)

 

Emax Ballmill

Kugelmühle

High Energy Ball Mill Emax, Retsch GmbH

Usages: chemical homogenizing, nano grinding, crystallite size reduction (down to ~20 nm). Integrated with water cooling system to prevent the sample from overheating.

  • Milling frequency = 300 - 1200 rpm
  • Milling time = maximum 6 h/day
  • Milling condition = dry / wet (with ethanol)
  • Milling jar
    • Material = WC (tungsten carbide)
    • Capacity = 50 mL (~20 mL should be left empty)
  • Milling balls
    • Material = WC (tungsten carbide)
    • Diameter = 2 mm
Ultimaker 2 Extended

Additive Fertigung (3D-Druck)

Ultimaker 2 Extended, Ultimaker

  • Filament-Drucker
  • Filamentdurchmesser: 2.85 mm
  • Filamente: PLA, PMMA unterschiedlich pigmentiert
  • Düsendurchmesser: 0.25 mm, 0.40 mm, 0.60 mm, 0.80 mm
  • Druckqualität: 0.015 mm
  • Maximale Druckbetttemperatur: 100 °C
  • Druckgeschwindigkeit: optimal 30 mm/s
Welding microscope

Welding Microscope

Welding microscope with PUK 3s professional, Lampert Werktechnik GmbH, Werneck Germany

  • Power consumption: 350 VA
  • Shielding gas: Argon
  • Magnification: 1 - 10x
Diamond wheel saw

Diamond Wheel Saw

Diamond wheel saw, Well Diamantdrahtsägen GmbH, Mannheim Germany